Plasma concentration of 3-hydroxyisovaleryl carnitine is an early and sensitive indicator of marginal biotin deficiency in humans.

Shawna L Stratton, Thomas D Horvath, Anna Bogusiewicz, Nell I Matthews, Cindy L Henrich, Horace J Spencer, Jeffery H Moran, Donald M Mock

Journal: The American journal of clinical nutrition 2010;92(6):1399-405

PMID: 20943794

Abstract

BACKGROUND

Blood-based indicators of biotin status in humans were shown to be useful tools in several clinical situations, including pregnancy. We previously validated the activity of the biotin-dependent enzyme propionyl-coenzyme A carboxylase (PCC) in lymphocytes as a sensitive and specific blood-based indicator of marginal degrees of biotin deficiency. However, the measurement of PCC activity in population studies presents substantial analytic challenges. 3-Hydroxyisovaleryl carnitine (3HIA-carnitine) increases in response to the decreased activity of the biotin-dependent enzyme methylcrotonyl-coenzyme A carboxylase and might reflect biotin status.

OBJECTIVE

We sought to determine whether the plasma concentration of 3HIA-carnitine increases significantly in marginal biotin deficiency.

DESIGN

We experimentally induced marginal, asymptomatic biotin deficiency in 10 healthy adults (8 women) by having the subjects consume undenatured egg white for 28 d; biotin status was then repleted. Plasma concentrations of 3HIA-carnitine were measured on days 0, 14, 28, 35, and 50 by liquid chromatography-mass spectroscopy.

RESULTS

The mean plasma 3HIA-carnitine concentration increased with depletion (P < 0.0001) and decreased with repletion (P < 0.0001). Plasma 3HIA-carnitine concentrations were greater than the upper limit of normal concentrations in 7 of 10 subjects by day 14 and in 9 of 10 subjects by day 28 and decreased to within normal limits in 9 of 10 subjects by day 50.

CONCLUSIONS

These studies provide evidence that 3HIA-carnitine is an early and sensitive indicator of marginal biotin deficiency. The ease of sample collection, small sample volume requirement, and stability of 3HIA-carnitine during storage suggest that plasma 3HIA-carnitine concentration is likely to be a useful indicator of marginal biotin deficiency for larger population studies.

Address: Departments of Biochemistry and Molecular Biology and Pediatrics and the Division of Biostatistics, University of Arkansas for Medical Sciences, Little Rock, AR, USA.
Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.