Bruno Gregori, Odysseas Papazachariadis, Alfonsa Farruggia, Neri Accornero
Journal: Journal of the neurological sciences 2011;300(1-2):130-4
PMID: 20875905
BACKGROUND
Optic neuritis related to multiple sclerosis and diabetic retinopathy are relatively selective post-retinal and retinal vision disorders. Vision impairment in both conditions is reliably measured by testing critical fusion frequency (CFF).
METHODS
To examine color vision, we measured the CFF in response to red and blue stimuli, and tested CFF values in patients without evident vision impairment. To ensure that differences in CFF values in a given subject depended only on color perception we displayed red and blue flickering stimuli at equal luminance. CFF to red or blue stimuli were compared in patients with medical history of optic neuritis related to multiple sclerosis (post-retinal vision impairment), patients with diabetic retinopathy (retinal vision impairment) and healthy subjects.
RESULTS
The test procedure disclosed altered CFF values for red and blue stimuli in both groups of patients studied. The comparison between the two groups disclosed a prevalent CFF impairment for red stimuli in patients with optic neuritis related to multiple sclerosis and for blue stimuli in patients with diabetic retinopathy.
CONCLUSIONS
The differential color flicker test appears highly accurate in detecting color vision impairment. Comparison of the two color CFFs differentiates retinal from post-retinal visual disorders.
Copyright © 2010 Elsevier B.V. All rights reserved.
© Copyright 2026, Nutrition Evidence