Precision of polyether ether ketone (PEEK) or cobalt-chrome implant bar fit to implants after mechanical cycling.

Eduardo V Silva Júnior, Roberta T Basting, Cecilia P Turssi, Fabiana Mg França

Journal: Acta odontologica latinoamericana : AOL 2023;36(2):71-77

PMID: 37776503

Abstract

UNLABELLED

Based on its mechanical properties, PEEK (polyether-ether-ketone) might be useful in restorative procedures. In oral rehabilitation, its viability has been studied mainly for prostheses and dental implants.

AIM

The aim of this study was to evaluate the fit accuracy of dental implant bars made of either PEEK or cobalt-chrome submitted to cycling mechanics.

MATERIALS AND METHOD

This was an experimental in vitro study, where units were treated with two implants and mini-abutments, joined by cobalt-chrome or polyether-ether-ketone PEEK bars. A total 20 bars were prepared (n=10 per group) and subjected to mechanical cycling tests (1 million cycles on the distal cantilever of the bar in the vertical direction, 120N and sinusoidal loading, at a frequency of 2Hz). The fit at the abutment/implant interface was measured before and after cycling, and the counter-torque of the vertical screw of the mini abutments was measured after cycling, using a digital torquemeter. Data were analyzed by three-way ANOVA and Tukey's test at 5% significance level.

RESULTS

No statistically significant interaction was found among the three factors considered (bar material, implant positioning and mechanical cycling) (p = 0.592). No significant difference was identified in the interaction between bar material and implant positioning (p = 0.321), or between implant positioning and mechanical cycling (p = 0.503). The association between bar material and mechanical cycling was statistically significant (p = 0.007), with the cobalt-chrome bar resulting in greater misfit with mechanical cycling. There was no difference in counter-torque values between groups.

CONCLUSIONS

The PEEK bar provided better fit of the mini abutments to the implants, even after mechanical cycling. The counter-torque of the screws was similar in all scenarios considered.

Address: Faculdade São Leopoldo Mandic, Programa de Pós-Graduação, Campinas, Brasil. [email protected].; Faculdade São Leopoldo Mandic, Programa de Pós-Graduação, Campinas, Brasil.; Faculdade São Leopoldo Mandic, Programa de Pós-Graduação, Campinas, Brasil. [email protected].