Dose planning study of proton versus photon radiotherapy for head and neck squamous cell carcinoma of unknown primary in the primary and recurrent setting.

Anne Ivalu Sander Holm, Ulrik Vindelev Elstrøm, Signe Bergliot Nielsen, Kenneth Jensen

Journal: Acta oncologica (Stockholm, Sweden) 2024;62(11):1412-1417

PMID: 37815913

Abstract

BACKGROUND

Patients with head and neck squamous cell carcinoma of unknown primary (HNCUP) are often treated with extensive radiotherapy (RT). Frequently, the bilateral nodal clinical target volume (nCTV) and the volumes of suspected mucosal primary sites (mCTV) of the pharynx and larynx is irradiated. This treatment is effective but toxic. New data suggest that omission of the contralateral nCTV and mCTV, results in few recurrences. The present study explores photon versus proton therapy, in the primary and recurrent setting.

MATERIAL AND METHODS

An analysis of twelve patients previously treated for HNCUP was performed. A fictitious recurrence was defined in patients treated for unilateral disease. Independently a volumetric arc photon plan and an intensity-modulated proton plan was made for all cases and scenarios.

RESULTS

Compared to the standard bilateral treatment this study shows that limiting the target to unilateral nCTV leads to a significant decrease in dysphagia of 18% and 17% and xerostomia of 4.0% and 5% for photon and protons, respectively. Comparing photon RT directly to proton RT shows a small and often insignificant gain, using protons for both bilateral and unilateral targets. Focusing on re-irradiation, benefits from using protons in both the primary setting and at re-irradiation were limited. However, using protons for re-irradiation only leads to a decrease in the tissue volume receiving a specific dose outside the target overlapping region, e.g., V90Gy was 31, 25, and 22 cm for photons-photons, photons-protons, and protons-protons, respectively. For V100Gy of the ipsilateral carotid artery, no differences were observed.

CONCLUSION

Omitting contralateral nCTV irradiation and mCTV irradiation will significantly reduce toxicity. The accumulated high dose volumes can be minimised using protons for re-irradiation. However, the use of protons for primary treatment provides limited benefit in most patients.

Address: Department of Oncology, Aarhus University Hospital, Aarhus, Denmark.; Danish Center for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.; Departments of Head and Neck Surgery & Experimental Clinical Oncology, Aarhus University Hospital, Aarhus, Denmark.

Link outs

Bant logo

© Copyright 2026, Nutrition Evidence

NED wishes to thank the following organisations for their support:

We use cookies to improve your experience and analyze site traffic with Google Analytics. By continuing to use our site, you agree to our use of cookies. Learn more.