-
1.
Obesity: how much does it matter for female pelvic organ prolapse?
Young, N, Atan, IK, Rojas, RG, Dietz, HP
International urogynecology journal. 2018;(8):1129-1134
Abstract
INTRODUCTION AND HYPOTHESIS The objective was to determine the association between body mass index (BMI) and symptoms and signs of female pelvic organ prolapse (POP). METHODS An observational cross-sectional study of 964 archived datasets of women seen for symptoms and signs of lower urinary tract and pelvic organ dysfunction between September 2011 and February 2014 at a tertiary urogynaecology centre in Australia was carried out. An in-house standardised interview, the International Continence Society Pelvic Organ Prolapse Quantification (ICS POP-Q) and 4-D translabial ultrasound, followed by analysis of ultrasound volumes for pelvic organ descent and hiatal area on Valsalva, were performed, blinded against other data. RESULTS There is a positive association between BMI and posterior compartment prolapse on clinical examination and ultrasound imaging, but not for the anterior and central compartments. There was no association with prolapse symptom bother and a negative association with symptoms of prolapse. CONCLUSIONS In this observational study, we found a strong association between all tested measures of posterior compartment descent and BMI, both clinical and on imaging.
-
2.
Characterization of coronary plaque regions in intravascular ultrasound images using a hybrid ensemble classifier.
Hwang, YN, Lee, JH, Kim, GY, Shin, ES, Kim, SM
Computer methods and programs in biomedicine. 2018;:83-92
Abstract
BACKGROUND AND OBJECTIVES The purpose of this study was to propose a hybrid ensemble classifier to characterize coronary plaque regions in intravascular ultrasound (IVUS) images. METHODS Pixels were allocated to one of four tissues (fibrous tissue (FT), fibro-fatty tissue (FFT), necrotic core (NC), and dense calcium (DC)) through processes of border segmentation, feature extraction, feature selection, and classification. Grayscale IVUS images and their corresponding virtual histology images were acquired from 11 patients with known or suspected coronary artery disease using 20 MHz catheter. A total of 102 hybrid textural features including first order statistics (FOS), gray level co-occurrence matrix (GLCM), extended gray level run-length matrix (GLRLM), Laws, local binary pattern (LBP), intensity, and discrete wavelet features (DWF) were extracted from IVUS images. To select optimal feature sets, genetic algorithm was implemented. A hybrid ensemble classifier based on histogram and texture information was then used for plaque characterization in this study. The optimal feature set was used as input of this ensemble classifier. After tissue characterization, parameters including sensitivity, specificity, and accuracy were calculated to validate the proposed approach. A ten-fold cross validation approach was used to determine the statistical significance of the proposed method. RESULTS Our experimental results showed that the proposed method had reliable performance for tissue characterization in IVUS images. The hybrid ensemble classification method outperformed other existing methods by achieving characterization accuracy of 81% for FFT and 75% for NC. In addition, this study showed that Laws features (SSV and SAV) were key indicators for coronary tissue characterization. CONCLUSIONS The proposed method had high clinical applicability for image-based tissue characterization.
-
3.
CEUS LI-RADS: algorithm, implementation, and key differences from CT/MRI.
Wilson, SR, Lyshchik, A, Piscaglia, F, Cosgrove, D, Jang, HJ, Sirlin, C, Dietrich, CF, Kim, TK, Willmann, JK, Kono, Y
Abdominal radiology (New York). 2018;(1):127-142
Abstract
Contrast-enhanced ultrasound (CEUS) is a specialized form of ultrasound (US) performed with an intravenous injection of microbubble contrast agents. It has been successfully used for a variety of applications including characterization of liver tumors. In April 2014, the American College of Radiology (ACR) convened a working group of international experts to develop ACR CEUS Liver Imaging Reporting and Data System (CEUS LI-RADS). An initial version of CEUS LI-RADS was published in August 2016. Although the CEUS LI-RADS concept and principles for liver lesion characterization, using dynamic contrast enhancement features, are similar to those for CT or MRI, there are significant differences between CT/MRI and CEUS LI-RADS. Therefore, CEUS LI-RADS has different diagnostic features and a unique characterization algorithm. The size of a lesion, the type and degree of arterial phase enhancement, the presence of washout, and the timing and degree of washout are the major features used for categorization. This paper describes key differences between CT/MRI and CEUS, and provides a diagnostic algorithm of CEUS LI-RADS with detailed, step-by-step instructions and imaging examples of CEUS LI-RADS categories.
-
4.
Contrast enhanced ultrasound for focal liver lesions: how accurate is it?
Barr, RG
Abdominal radiology (New York). 2018;(5):1128-1133
Abstract
With the recent FDA approval for characterization of focal liver lesions (FLL) in both pediatric and adult patients using Lumason (sulfur hexafluoride microbubbles), increased use of ultrasound contrast for routine clinical use is expected. This agent has been available for many years in Europe and Asia, and a large body of literature is available regarding the sensitivity and specificity of this agent. In addition, a few studies have directly compared CEUS to CECT and CEMRI for the characterization of focal liver lesions. This paper reviews the literature to provide a background to investigators in the United States as to the accuracy of CEUS in the characterization of FLL. This paper reviews the literature regarding sulfur hexafluoride microbubbles (Lumason in the USA and Sonovue in the rest of the world) since it is the only FDA approved agent in the USA for characterization of FLL. The results of other ultrasound contrast agents which are not FDA approved for abdominal indications (approval for cardiac indications) most likely will have similar results.
-
5.
Reliability of ultrasound measurements of quadriceps muscle thickness in critically ill patients.
Pardo, E, El Behi, H, Boizeau, P, Verdonk, F, Alberti, C, Lescot, T
BMC anesthesiology. 2018;(1):205
Abstract
BACKGROUND Muscle wasting in critically ill patients is associated with negative clinical outcomes. Ultrasound quadriceps femoris muscle assessment may constitute a convenient tool to evaluate muscle wasting. Nevertheless, its reliability remains uncertain. Our primary aim was to study the intra- and inter-observer reliability of this technique. Our secondary aim was to assess the evolution of the quadriceps muscle during the first 3 weeks after ICU admission and its possible association with nutritional intake. METHODS This observational study included patients expected to stay more than 7 days in the ICU. Ultrasound quadriceps muscle thickness was measured with a 12 MHz linear transducer, by two trained physicians, on D1, D3, D5, D7 and D21. Two measurements sites were evaluated: on the midpoint or on the two-thirds of the length between the anterior superior iliac spine and the upper border of the patella. Intra and inter-observer reliability was assessed by calculating the intra-class correlation coefficient (ICC). RESULTS A total of 280 ultrasound quadriceps thickness measurements were performed on 29 critically ill patients. Intra-observer reliability's ICC was 0.74 [95% CI 0.63; 0.84] at the "midpoint" site and 0.83 [95% CI 0.75; 0.9] at the "two-thirds" site. Inter-observer reliability's ICC was 0.76 [95% CI, 0.66; 0.86] at the "midpoint" site and 0.81 [95% CI, 0.7; 0.9] at the "two-thirds" site. Quadriceps femoris muscle thickness decreased over 16% within the first week after ICU admission. No correlation was found between muscle loss and caloric (p = 0.96) or protein (p = 0.80) debt over the first week. CONCLUSION The assessment by ultrasonography of the quadriceps muscle thickness reveals good intra- and inter-observer reliability and may constitute a promising tool to evaluate the effect of nutritional-based interventions on muscle wasting in critically ill patients. TRIAL REGISTRATION "Committee for the Protection of Human Subjects in Biomedical Research" - Paris Ile de France VI Pitié-Salpêtrière - 10/07/2014. French Data Protection Committee ("Commission Nationale Informatique et Libertés") - #1771144.
-
6.
Contrast enhanced ultrasound (CEUS) imaging of solid benign focal liver lesions.
Dietrich, CF, Tana, C, Caraiani, C, Dong, Y
Expert review of gastroenterology & hepatology. 2018;(5):479-489
Abstract
Ultrasound is well accepted worldwide for imaging of the liver. Absences of radiation exposure, low cost and large diffusion are some of the advantages that make this technique the first to be used in the assessment of focal liver lesions (FLL). Areas covered: Contrast enhanced ultrasound (CEUS) has been introduced more than twenty years ago, and its detection rate is comparable to that of contrast enhanced magnetic resonance imaging (CEMRI) and contrast enhanced computed tomography (CECT). In this narrative review, we discuss the main CEUS features of benign liver lesions and controversies in published results including the gold standard chosen and the quality and knowledge of the preferred techniques. Expert commentary: CEUS is safe and allows an immediate evaluation of the nature of FLL. CEUS permits differentiation between malignant and benign FLL in healthy liver parenchyma by analysing the arterial, portal venous and late phases. CEMRI and CECT are reliable to characterize FLL but higher costs, radiation exposure, nephrotoxicity (in particular for CECT) and absence of real time imaging limit the appropriate evaluation of FLL. Therefore CEUS can be preferred in most clinical situations, and when results are unclear or suggestive for malignant FLL, biopsy and histological examination can be directly initiated avoiding unnecessary additional imaging.
-
7.
Point-of-Care Ultrasound Diagnosis of Retinoblastoma in the Emergency Department.
Giacalone, M, Mastrangelo, G, Parri, N
Pediatric emergency care. 2018;(8):599-601
Abstract
An 18-month-old girl presented to the emergency department with the chief complaint of squinting. The right eye demonstrated esotropia, heterochromia, and anisocoria. Ocular point-of-care ultrasound facilitated the rapid diagnosis of retinoblastoma, which was confirmed by computed tomography scan and orbital magnetic resonance imaging.
-
8.
US of Pediatric Superficial Masses of the Head and Neck.
Bansal, AG, Oudsema, R, Masseaux, JA, Rosenberg, HK
Radiographics : a review publication of the Radiological Society of North America, Inc. 2018;(4):1239-1263
Abstract
Superficial palpable masses of the head and neck are common in the pediatric population, with the vast majority of the lesions ultimately proven to be benign. Duplex ultrasonography (US) has emerged as the first-line imaging modality for the evaluation of superficial pediatric masses. Without utilizing radiation, iodinated contrast material, or sedation and/or anesthesia, US provides a means for quick and cost-effective acquisition of information, including the location, size, shape, internal content, and vascularity of the mass. In this review, the US findings are described for a variety of common and uncommon pediatric head and neck masses diagnosed in our practice. Specifically, the entities covered include neonatal scalp hematoma, craniosynostosis, dermoid and epidermoid cysts, Langerhans cell histiocytosis, lymph nodes and their complications, fibromatosis colli, thyroglossal duct cyst, branchial cleft cyst, cervical thymus, congenital goiter, thyroid papillary carcinoma, parathyroid adenoma, hemangioma, lymphangioma, jugular vein phlebectasia, Lemierre syndrome, acute parotitis and parotid abscess, leukemia and/or lymphoma, neurogenic tumor, and rhabdomyosarcoma. Ultimately, in situations in which the head or neck mass is too large, deep, or hyperechoic to be fully assessed within the US field of view, or if malignancy or a high-flow vascular lesion is suspected, then further evaluation with cross-sectional imaging is warranted. Online supplemental material is available for this article. ©RSNA, 2018.
-
9.
Limited additional value of cervical ultrasonography over a negative 18F-FDG PET/CT for diagnosing cervical lymph node metastases in patients with esophageal cancer: a systematic review and meta-analysis.
Goense, L, Meziani, J, van Rossum, PSN, Wessels, FJ, Meijer, GJ, Lam, MGEH, van Hillegersberg, R, Ruurda, JP
Nuclear medicine communications. 2018;(7):645-651
Abstract
OBJECTIVE To assess the additional value of cervical ultrasonography as supplement to a negative fluorine-18-fluorodeoxyglucose (F-FDG) PET/computed tomography (CT) for detecting cervical lymph node metastases during the initial staging of patients with esophageal cancer. METHODS PubMed/Medline, Embase, and the Cochrane library were systematically searched. The analysis included diagnostic studies describing the accuracy of cervical ultrasonography and integrated F-FDG PET/CT or standalone F-FDG PET and CT for detecting cervical lymph node metastases in patients with esophageal cancer. The reference standard consisted of cytopathology and/or clinical follow-up. The Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess the quality of the included studies. A random effects model was used to meta-analyze the additional diagnostic value of cervical ultrasonography. RESULTS Four diagnostic studies were eligible and included for meta-analysis, comprising 567 patients with esophageal cancer who underwent diagnostic workup before treatment. The quality of the included studies was considered reasonable; there were few concerns regarding risk of bias and applicability. In three of the four studies, cervical ultrasonography did not detect cervical lymph node metastases in addition to a negative finding on F-FDG PET/CT or standalone F-FDG PET and CT. In one study, cervical ultrasonography detected additional cervical lymph node metastases in 4% (3/74) of patients over standalone F-FDG PET and CT. Pooled estimate of the additional value of cervical ultrasonography was 1% (95% confidence interval: 0-5%). CONCLUSION Cervical ultrasonography has very limited additional diagnostic value as supplement to a negative F-FDG PET/CT in the detection of cervical lymph node metastases during the initial staging of patients with esophageal cancer.
-
10.
Gavage Feed Volume Determines the Gastric Emptying Rate in Preterm Infants.
Ferreira, CHF, Martinez, FE, Crott, GC, Belik, J
Journal of pediatric gastroenterology and nutrition. 2018;(3):e43-e46
Abstract
OBJECTIVE Feeding intolerance, manifesting as increased gastric residual, is a common finding in preterm neonates. Little is known about the regulation of gastric emptying early in life and the extent to which this plays a role in the preterm infants' feeding tolerance. The goal of this study was to evaluate clinically stable 28- to 32-week gestation neonates during the first 4 weeks of life and noninvasively determine their gastric emptying rate. STUDY DESIGN Ultrasound measurements of gastric milk content volume were obtained from 25 neonates immediately after, 30 and/or 60 minutes following routine gavage feeds. The content emptying rate was calculated from the gastric volume data. RESULTS Gastric emptying rate was not postnatal age-dependent, was significantly higher at 30 minutes, whenever compared with 60-minute postfeed and directly proportional to the feed volume. At any postnatal age, the gastric emptying rate was at least 6-fold greater, when comparing the lowest and highest average stomach content volumes. CONCLUSIONS The gastric emptying rate of preterm infants is content volume-dependent and unrelated to the postnatal age. Given the present findings, further investigation on the gastric residual of preterm infants receiving larger than currently administered feed volumes at the initiation of enteral nutrition, is warranted.